Ground Fault Systems Services

Ground Fault Systems

Ground faults—unintended current paths from an energized conductor to ground—are among the most common and destructive electrical hazards in commercial and industrial facilities, capable of causing violent arcing faults and equipment fires. National Electrical Code (NEC) regulations mandate ground fault protection (GFP) on specific low-voltage distribution systems to limit this risk. Critical Switchgear Services (CSS) delivers specialized testing, calibration, preventative maintenance, and repair for industrial ground fault protection systems. Operating across Colorado and New Jersey, our certified technicians ensure your GFP relays, sensors, and shunt-trip breakers operate with absolute precision, protecting your facility from catastrophic arcing events while preventing costly nuisance tripping.

System Start-Up & Commissioning

Commissioning ground fault protection systems requires absolute precision to ensure the system detects dangerous ground faults without tripping under normal operating leakage currents. CSS provides expert start-up and commissioning for new GFP installations across Colorado and New Jersey. Our technicians verify sensor (CT) polarity and wiring, check neutral-to-ground bond locations (ensuring no downstream secondary neutral-to-ground bonds exist to cause nuisance trips), and calibrate pickup and time-delay settings in strict compliance with NEC and engineering specifications.

Contact Us Today!

Acceptance Testing & Secondary Injection Calibration

Before energizing low-voltage switchboards equipped with ground fault protection, NETA acceptance testing is mandatory. CSS executes rigorous secondary injection testing on all ground-fault relays and sensing schemes. Using specialized test sets, we inject precise test currents into the relay circuitry to verify exact pickup current levels and time-delay tripping curves. We also perform primary current injection testing where feasible to verify the entire loop from sensor to breaker trip coil, ensuring your GFP system will function flawlessly during an actual ground fault event in your Colorado or New Jersey facility.

Preventative Maintenance & Nuisance Trip Troubleshooting

Ground fault protection systems require periodic testing to ensure components have not drifted or degraded. CSS offers structured preventative maintenance programs tailored to industrial GFP infrastructure. Our service visits include functional trip testing via test buttons or secondary injection, sensor wiring checks, and control circuit verification. If your facility is experiencing unexplained nuisance tripping that disrupts production, our diagnostic engineers troubleshoot complex grounding loops, harmonic interference, and transient voltage issues to resolve the problem permanently.

Repair, Upgrades & Control Circuit Overhaul

When a ground fault relay fails or a trip mechanism malfunctions, your facility is either left unprotected against arcing faults or plagued by unmanageable outages. CSS provides rapid repair, replacement, and system upgrade services for ground fault systems throughout Colorado and New Jersey. Whether you need to replace damaged zero-sequence current sensors, upgrade legacy analog GFP relays to modern digital units, or overhaul control wiring harnesses, our technicians deliver expert industrial-grade solutions to restore safe, compliant electrical protection.

Neta Accredited Company Logo
Skip to content
Critical Switchgear Services
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.